This Gold Phoenix PCB Knowledge Center article explains safe distance requirements in PCB design, including electrical clearance (space distance), creepage distance (distance along the surface) and insulation penetration distance.
Electrical clearance is the shortest distance between two adjacent conductors or between one conductor and the surface of an adjacent motor housing.
The distance is determined based on the measured operating voltage and insulation level. Typical guidelines are as follows:
Primary (AC) side:
L-N (before fuse): ≥ 2.5 mm
L, N to PE (earth): ≥ 2.5 mm
After fuse: no strict requirement, but maintain a certain distance to avoid short circuit damage to the power supply
Primary AC to DC part: ≥ 2.0 mm
DC side to earth: ≥ 2.5 mm (primary side floating grounding to earth)
Primary to secondary side: ≥ 4.0 mm. Cross-components connected between primary and secondary sides with an electrical clearance of ≥ 0.5 mm may be considered part of the secondary side.
Secondary to earth: ≥ 1.0 mm
Note: To verify whether requirements are met, internal parts should be tested with a 10 N force, and the enclosure with a 30 N force, to reduce the distance and confirm that in the worst case the space distance still complies with specifications.
Creepage distance is the shortest distance between two adjacent conductors or between one conductor and the surface of an adjacent motor housing along the insulated surface.
1. Primary AC part: L-N (before fuse) ≥ 2.5 mm; L, N to earth (after fuse): no strict requirement, but maintain a certain distance to avoid short circuit damage to the power supply
2. Primary AC to DC part: ≥ 2.0 mm
3. DC to earth (primary side): ≥ 4.0 mm
4. Primary to secondary side: ≥ 6.4 mm. Components such as Y-capacitors with footing spacing ≤ 6.4 mm require slotting
5. Secondary part to part: ≥ 0.5 mm
6. Secondary to earth: ≥ 2.0 mm
7. Class II transformer: ≥ 8.0 mm
The following requirements shall be met according to the working voltage and the insulation application:
Operating voltage ≤ 50 V (71 V AC peak or DC): no specific voltage requirement
Additional insulation: minimum thickness of 0.4 mm
Reinforced insulation: minimum thickness of 0.4 mm, provided that no mechanical stress may cause deformation or deterioration of the insulation at normal temperatures, and the insulation is provided in a protective enclosure
For additional insulation, use at least two layers of material, each of which can be tested by the electrical strength test of additional insulation; or use three layers of insulating material in which any combination of two layers can be tested by the electrical strength test.
For reinforced insulation, use at least two layers of material, each of which can be tested by the dielectric strength test of reinforced insulation; or use three layers of insulating material in which any combination of two layers can be tested by the dielectric strength test of reinforced insulation.
Flat surface components such as capacitors must be mounted flat without adhesive dispensing
If two conductors can be brought closer under a 10 N force to less than the safe distance requirement, adhesive dispensing can be used to fix parts and ensure electrical clearance
When PVC film is used inside the enclosure, pay attention to safe distance requirements during processing
When adhesive dispensing is used to fix parts, ensure no foreign bodies (such as silk) are present on the PCB board
Insulation failures should not be caused during machining of parts
| Material | Minimum Rating |
|---|---|
| Heat shrinkable casing | V-1 or VTM-2 or higher |
| PVC casing | V-1 or VTM-2 or higher |
| Teflon sleeve | V-1 or VTM-2 |
| Plastic materials (silicon film, insulating tape) | V-1 or VTM-2 |
1. Working insulation: The insulation needed for the normal operation of the equipment
2. Basic insulation: Insulation to provide basic protection against electric shock
3. Additional insulation: Separate insulation applied in addition to basic insulation to protect against electric shock when basic insulation fails
4. Double insulation: Insulation consisting of basic insulation plus additional insulation
5. Reinforced insulation: A single insulation structure that provides protection against electric shock equal to double insulation under the specified conditions
← Back to PCB Design Tutorial
Capacités
Capacité PCB rigide
Capacité PCB flexible
Capacité d'assemblage PCB
Équipement PCB
Équipement d'assemblage PCB
Méthodes de paiement
Prix spéciaux
Transporteurs
Support pour amateurs
Certificat
Assistance clientèle
Suivez-nous
Tel: 1-905-339-2881
Email: sales@goldphoenixpcb.com , tech@goldphoenixpcb.com
Copyright Gold Phoenix PCB Co., Ltd. 2011 - 2026
Tel: 1-905-339-2881 Email: sales@goldphoenixpcb.com , tech@goldphoenixpcb.com
Système de contrôle qualité | Service produit
| Liens
Copyright Gold Phoenix PCB Co., Ltd. 2011 - 2026